Self-checking ideas

Service corresponding function

Each microservice of BKCI corresponds to each function. If a function is abnormal, check the corresponding service logs first. Service log paths refer to basic concepts

microservicefunction

gateway

BKCI gateway

artifactory

Artifact Services, the default artifact repository

dockerhost

Common builder

environment

Private builder service. Import and manage the builder

process

pipeline

project

Project management

plugin

The plug-in of the service extends the service

repository

Code base

ticket

Certificate management

store

Research and development store

image

Public builder image

dispatch

Private builder scheduling

dispatch-docker

Common builder scheduling

agentless

Non-compile environment

auth

authentication

log

Build log

notify

BKCI has built-in notification services

openapi

BKCI API service

For detailed component descriptions and associations, see bkci Components

Troubleshooting example

Problem background

  1. The upload product cannot be displayed when the pipeline is executing

  2. And plugins occasionally report errors

Troubleshooting idea

① : Check build logs

Obtain build logs corresponding to the build and rectify the fault. For details about how to obtain logs, see Basic Concepts

When checking build logs, you can search by the plug-in name that reports an error to locate the fault. For example, if the Upload package plug-in reports an error, we can try to query the upload field in the log to search the corresponding log executed by the upload. Then, the following error logs are displayed:

2: Check service logs

According to the build log, you can see that the build request artifactory service times error, so check the artifactory log.

  1. Check service logs. Check the error logs first. If obvious errors are reported, rectify them directly. If no error is reported, continue to check service logs.

  2. Service logs are located based on the time when a build log error occurs

When checking logs, two obvious errors are found:

In this case, continue to check the process service. Subsequent checks show that during the construction of the process service, the load pressure of the CI machine is too high, resulting in an exception of the service.

solve

  1. According to the log, the process service is restarted.

  2. If No Space left on device was reported, the space of CI machine was cleared.